Zirconia Type Oxygen Analyzers (O2 Meters)

TF-10

TF-10 Probe Transmitter
TF-10 Probe Transmitter
DTF-102 Receiver
DTF-102 Receiver

Features

  • Can be inserted directly into the furnace for measurement, eliminating the need for sampling piping and pretreatment equipment
  • No standard gas or reference air required (Calibration can be performed using air-point calibration)
  • Compact and lightweight design with automatic calibration function for easy maintenance

Usage

Monitoring and control of the following combustion processes and atmospheres:

Boiler combustion exhaust gas
  • Small- and medium-sized boilers, black liquor recovery boilers, etc.
Incinerator exhaust gas
  • At the outlet of cooling towers for waste and sludge incinerators (Dedicated models TF-III and TF-IV are available for high-temperature furnace outlet sections)

Specifications

Model TF-10D102 (TF-10 Probe Transmitter + DTF-102 Receiver)
Measuring Principle Zirconia type limiting current method
Sampling Method Direct insertion
Measuring Range 0–5 / 0–10 / 0–25% (System data change required for 0–5% range)
Accuracy Repeatability ±0.5% FS
Linearity ±2% FS (0–5 / 0–10% range), ±1% FS (0–25% range)
Response Time ≤5 seconds (probe length ≤1.0 m), ≤7 seconds (probe length 1.5 m)(90% response when switching calibration gas)
Analog Output DC 4–20 mA, isolated output, load resistance ≤550 Ω
Calibration Air-point calibration (no standard gas required)
Contact Input Voltage-free contacts
Number of contacts: 3 inputs
Selectable functions: Calibration start / Purge start / Range switching / Output hold / Sleep mode
Contact Output Voltage-free relay contacts (AC 250V 1A / DC 30V 1A, resistive load)
Number of contacts: 4 outputs
Selectable functions: Analyzer fault / H range / High concentration alarm / Low concentration alarm / Ready (normal measurement) / Under maintenance / Air cal. / Span cal. / Zero cal. / Purge / Air cal. or Purge / High-low concentration alarm / Analyzer fault or High-low concentration alarm
Other Functions Manual calibration / Remote calibration / Automatic calibration / First-order lag calculation / Moving average calculation / Output hold / High-low concentration alarm / Self-diagnostics / Simulated output / Analog output adjustment
Power Supply AC 100–240 V, 50/60 Hz, 50 VA
Transmitter Interface Mounting flange: JIS 5K 50A to JIS 10K 125A (Contact us for other sizes)
Probe Insertion Length 0.5 / 1.0 / 1.5 m
Calibration Unit Automatic calibration available when combined with DTF-102 Receiver
(Air pump, solenoid valve, and flowmeter integrated in unit panel)

Resources

Instruction Manuals

Product Inquiries